Memory problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problem issolved.v See Chapter 5, “Parts listing, System x3750 M4 Types 8722 and 8733,” on page 195 to determine whichcomponents are customer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by aTrained service technician.Symptom ActionThe amount of system memorythat is displayed is less than theamount of installed physicalmemory.Note: If you change memory, you must update the memory configuration in theSetup utility (see “Using the Setup utility” on page 127 for more information). Formore information about installing DIMMs, see “Installing a memory module” onpage 41, “Non-mirroring (independent mode)” on page 44, “Memory mirroring”on page 44, and “Memory sparing” on page 45.1. If the server was recently installed, moved, or serviced, make sure that allDIMMs are seated correctly.2. If a new DIMM has been installed recently, verify that you have not receivedany configuration events in the event log. Otherwise, check the IMM event log.If any DIMM configuration events are listed, resolve the event problems first.3. Make sure that:v No error LEDs are lit on the operator information panel or on themicroprocessor and memory expansion tray.v Memory mirroring does not account for the discrepancy (see “Memorymirroring” on page 44).v The memory modules are seated correctly (see “Removing a memorymodule” on page 223 and “Replacing a memory module” on page 224).v You have installed the correct type of memory (see “Installing a memorymodule” on page 41).v If you changed the memory, you updated the memory configuration in theSetup utility.v All banks of memory are enabled. The server might have automaticallydisabled a memory bank when it detected a problem, or a memory bankmight have been manually disabled.4. Check the POST event log:v If a DIMM was disabled by a systems-management interrupt (SMI), replacethe DIMM.v If a DIMM was disabled by the user or by POST, run the Setup utility andenable the DIMM.5. Run memory diagnostics (see “IBM Dynamic System Analysis” on page 169). Ifan error is detected, follow the steps to correct the error.6. For the system board and microprocessor and memory expansion tray, addDIMMs one at a time ( see “Replacing a memory module” on page 224).7. Reseat the DIMM.8. Restart the server.Multiple rows of DIMMs in abranch are identified as failing. 1. Check the system-event log for any events associated with a failing DIMM.2. Resolve the DIMM errors listed in the system-event log, starting with the firsterror that has occurred.3. Resolve any DIMM configuration mismatches that are listed in the IMM eventlog.180 System x3750 M4 Types 8722 and 8733: Installation and Service Guide