c. Gently push the drive-tray assembly into the bay until the drive stops.d. Rotate the drive-tray handle to the closed (locked) position.4. Installing a 1.8-inch hot-swap drive:a. Insert the drive into the drive bay with the label side of the drive facing theright side of the server.b. Push the drive tray into the drive bay and rotate the drive tray handle tothe closed position and ensure that the latch is in the locked position.5. Reinstall the drive filler panel.6. Check the drive status LED to verify that the drive is operating correctly. If theamber drive status LED for a drive is lit continuously, that drive is faulty andmust be replaced. If the green drive activity LED is flashing, the drive is beingaccessed.Note: If the server is configured for RAID operation using a ServeRAIDadapter, you might have to reconfigure your disk arrays after you install drives.See the ServeRAID adapter documentation for additional information aboutRAID operation and complete instructions for using the ServeRAID adapter.7. If you are installing additional hot-swap drives, do so now.8. Turn on the peripheral devices and the server.Removing a CD/DVD driveTo remove a CD/DVD drive, complete the following steps:1. Read the safety information that begins on page “Safety” on page vii and“Installation guidelines” on page 33.2. Turn off the server (see “Turning off the server” on page 21) and all attachedperipheral devices. Disconnect all power cords; then, disconnect all externalcables as necessary to replace the device.3. Remove the server cover (see “Removing the server top cover” on page 206).4. Press and hold the release tab down as you push the drive from the rear toslide it out of the bay.Chapter 6. Removing and replacing components 217