C-9ICP Flash Utility (IFU)ExampleThe following example displays version information about allsupported controllers.A:\> IFU VERSION /C 0ICP Flash Utility V4.0-0 B5749(c)ICP Inc. 1999–2005. All Rights Reserved.Version Information for Controller #0 (ICP9024RO)ROM: Build 5748 [VALID] Fri Sep 27 13:28:40 EDT 2002A:\> IFU VERSION /C ALLIFU Command Line – Step-by-StepThis section provides step-by step instructions for updating theflash.To update the flash using the IFU command line:1 Create the firmware floppy disks, as described in Creating theFirmware Floppy Disks on page C-3.2 Shut down the computer.3 Insert the bootable disk that contains the IFU utility.4 Turn on the computer.5 Enter the system setup utility and verify that your computer isset up to boot from the bootable disk.6 If you have multiple controllers only—At the DOS prompt, typeifu list and press Enter.This command displays the ICP RAID controllers in yoursystem. Note the controller number for the controller you wantto update; you may need it in Step 7 to perform the update.7 You can update the flash using any of the followingalternatives:a Updating the Flash on a Single Controller—To flash thefirmware on a single controller, type:ifu update /C <controller_number>Where <controller_number> is the number of the controllerwhose firmware you are updating. For example, to upgradecontroller 0, type:ifu update /C 0