Section: 3IDS X-series LCD Keypad User Manual 700-411-01D Issued August 2010103.3 How to Stay Arm and Go(Hold down the [6] key for two seconds until the keypad buzzer sounds)This is a single key arm function, which allows the user to STAY arm and leave the premises.If a partition is already stay armed, holding down the [6] key initiates an exit delay, thus allowing the userto leave the premises without disarming. At the end of the exit delay, the partition will re-arm in the samestay profile it was armed in before the [6] key was held down.1. Make sure all zones are clear. Hold down the [6] key until the keypad buzzer sounds. The LCDdisplay reads „Exit Delay‟ alongside the partition number being armed. Any zones that have beenbypassed will be displayed on the LCD display as solid text. Any zones that are violated will bedisplayed on the LCD display as flashing text. Use the [PANIC] and [MED] keys to scroll throughzones that have been bypassed or violated. The keypad buzzer will sound for the duration of theexit delay. Only leave via a designated exit route.2. At the end of the exit delay, the ARM LED will come on and the display will read „Stay Armed‟. Allstay zones will be bypassed.3.4 Key-Switch or Remote Arming (If fitted)1. Ensure that the LCD display reads „Ready to Arm‟ before leaving.2. Leave the premises and lock the door.3. Activate the remote or the key-switch. A remote can be used to Stay Arm or Away Arm.4. The alarm will arm in the away mode.NOTE:If a remote control is used, it is advisable to have the siren toot on arm function enabled. This providesverification that the system has armed.3.5 Auto ArmingThe panel may be programmed to arm automatically at a pre-programmed time. Should the premises beoccupied at the time of auto arming, a valid [USER CODE] entered during the pre-arm delay willterminate the arming sequence. The pre-arm delay is signalled by an exit beep.