Section: 12IDS X-series LCD Keypad User Manual 700-411-01D Issues August 20102612. Viewing Trouble Conditions(Hold down the [7] key for two seconds until the keypad buzzer sounds)The user is alerted to a trouble condition via the flashing of the POWER LED. It is also possible to enablea trouble beep. If the trouble beep has been enabled, the keypad buzzer will sound to alert the user that atrouble condition has occurred. Press the [#] key to silence the buzzer. Hold down the [7] key for twoseconds. The LCD keypad will display what the trouble conditions are. The system will automatically exitthe TROUBLE VIEWING MODE after one minute. Alternately, to exit this mode, press the [#] key.NOTE:Certain trouble conditions will only clear once the trouble condition has restored. To cancel the beepingwithout viewing the trouble conditions, press the [#] key.Table 7: Trouble ConditionsZone LED Trouble Condition1 Panel AC Supply Failure2 Panel Communications Failure3 Telephone Line Trouble4 Siren Tamper5 Low Battery6 Aux 12V Resettable Fuse Blown7 Engineer reset8 Box tamper9 Peripheral Device Tamper10 Peripheral Communications Failure11 Peripheral Low Supply Voltage12 EEPROM chip failure13. Changing a Partition[MODE] [1] [*] [PARTITION NUMBER] [*]To change partitions the keypad must be assigned to access the required partition.1. Hold [MODE] until the keypad beeps.2. The LCD display reads „Mode Number + *‟.3. Press the [1] key followed by the [*] key.4. The LCD display reads „Partition +*‟.5. Enter the [PARTITION NUMBER], followed by the [*] key.6. The LCD display reads „P(number)‟.The keypads may be partitioned to remain in the new partition. Any value outside of these constraints willresult in a key entry error occurring.