AM-800CL / AB-800CL- 29 -7.2.1 ModeThe AM-800CL and AB-800CLhave the following exposure modes.1. EM=0 OFF2. EM=1 Timed3. EM=2 Trigger width7.2.2 Exposure time setting (Command: PE)PE command can be set if EM (Exposure mode) is set at 1 or 2.Minimum exposuretime ~ Maximum exposuretimeFull pixels10μs ~ 2 sec(Note)Binning(HxV)1 x 22 x 12 x 2Note: The AM-800CL and AB-800CL are designed so that frame rate has priority overexposure time. Accordingly, if the exposure time is set at a longer accumulation time than1 frame (58.7326ms), the frame rate should be set at a longer time than the exposure time.7.2.3 Exposure sequence (Commands EXSQ,PES(N), PER(N), EXSR, EXSEP, PE1 ~PE16)Up to 16 exposure settings can be preset as a sequence. Each setting can also be repeated.This function is effective only when the trigger mode is ON, the exposure mode is set toTimed and the exposure sequence is ON.7.3. Trigger Control7.3.1 Selection of the trigger input(Command: TI)The command “TI” can select the trigger input. At TI=0, the input through Camera Link(line 0) is active and at TI=1, the input through the Hirose 12-pin connector is active. Thefactory default setting is the Camera Link input.7.3.2 Trigger activation(Command: TA)The command “TA” can select how to activate the trigger.TA=0 Rising edge At the rising edge of the pulse, the accumulation and thereadout will start.TA=1 Falling edge At the falling edge of the pulse, the accumulation and thereadout will start.If Exposure Mode(EM) is set to EM=2 Trigger Width)TA=0 High During the high level of trigger, the accumulation is activatedand at the low level, the read out is activated.TA=1 Low During the low level of trigger, the accumulation is activatedand at the high level, the read out is activated.