AM-800CL / AB-800CL- 44 -9. Configuring the camera9.1 RS-232C controlAll configuration of the AM-800CL and AB-800CL cameras are done via Camera Link. Thecamera can be set up from a PC running terminal emulator software, or using JAI´s cameracontrol software.Below is the description of the ASCII based short command protocol.9.2 Communication setting.Protocol.Transmit setting to camera:NN=Parameter (NN is any kind of command. Capital or small letters.)The camera answers:COMPLETENote: Some commands can only be requested.Transmit request command to camera:NN? (NN is any kind of command.)The camera answers:NN=ParameterTransmit the following to have the camera‟s actual settings:ST?The camera answers:A complete list of the current settingsTransmit the following to have a command list:HP?The camera answers:A list with all commands and possible settingsInvalid parameters sent to camera: (99 is an invalid parameter)SH=99The camera answers:02 Bad Parameters!!To see firmware number.VN?To see camera ID. It shows the manufacturing lot number.ID?Baud Rate 9600 bpsRS 232C cableData Length 8 bitStart Bit 1 bitStop Bit 1 bitParity NoneXon/Xoff Control NoneTXDRXDGND1 CD4 DTR6 DSR2 RXD3 TXD5 GND7 RTS8 CTS9 CI9 pinD-conPC COMPORTCAMERA TXDRXDGND1 CD4 DTR6 DSR2 RXD3 TXD5 GND7 RTS8 CTS9 CI9 pinD-conPC COMPORTCAMERA