13 MANAGING DEVICES ON AN IP NETWORK (SNMP) / 13.2 SNMP Troubleshooting190FUNC (E)/ Ver 2.00OID (Object Identifier) Name Description Trouble Shooting1.3.6.1.4.1.46861.1.1.2.1.8.2 Fan Error Detection Is output when the fan canno longer spin.Confirm the fan status. If afan error cannot beconfirmed, contactJVCKENWOOD salescompany technical staff.1.3.6.1.4.1.46861.1.1.2.2.7.2 Power Supply VoltageStatusIs output when the powersupply voltage goes belowthe lower limit of thethreshold.Confirm if the power cord,etc. is connected to therepeater and if the value ofthe power supply voltage iswithin the specificationrange.1.3.6.1.4.1.46861.1.1.2.3.1.2 PLL Unlock Detection(RX)Is output when the RX PLLunlocks.Restart the repeaterbecause the PLL IC maynot have the correct dataconfiguration.Or, execute Tuning Data >Restore of the FPU.1.3.6.1.4.1.46861.1.1.2.3.2.2 PLL Unlock Detection(TX)Is output when the TX PLLunlocks.Restart the repeaterbecause the PLL IC maynot have the correct dataconfiguration.Or, execute Tuning Data >Restore of the FPU.1.3.6.1.4.1.46861.1.1.2.4.3.2 Current Consumption(HPA) ErrorIs output when an error inthe HPA currentconsumption is detected.If this problem occurs,contact JVCKENWOODsales company technicalstaff.1.3.6.1.4.1.46861.1.1.2.5.5.2 Temperature (DriveAmp) ErrorIs output when an error inthe Drive Amp temperatureis detected.Stop the repeatertransmission and confirm ifthe symptom improves.If the symptom does notimprove, contactJVCKENWOOD salescompany technical staff.