21 ERROR MESSAGE LIST FROM REPEATER230FUNC (E)/ Ver 2.0021 ERROR MESSAGE LIST FROM REPEATERTable 21-1 Error Message ListError Code Item Condition of Occurrence ThresholdE001 Unprogrammed When all Channel are Blank N/AE002 USB Overcurrent When an overcurrent occurs in theconnected USB device500 mAE003 TX Frequency Data Blank When an attempt is made to transmit on aChannel whose transmit frequency isBlankN/AE004 ESN Blank When the ESN is not written N/AE005 Firmware Startup Error When startup does not occur even in theforced PG modeN/AE006 Feature Error When a Software Option function which isnot permitted in the repeater is permittedin the FPU configurationN/AE007 Force Firmware ProgrammingModeWhen the rewriting of the firmware fromthe Web Tool is on standby after thewriting of the firmware fails and startupoccurs by using the saved old firmwareN/AE008 DSP Error 1 When the DSP cannot be started forsome reasonN/AE009 DSP Error 2 When the DSP does not have a library touseWhen the DSP is oldN/AE102 Hot Standby LAN ConnectionErrorWhen communication between a MainRepeater and Sub Repeater is interruptedFailsoft ModeWait TimerE103Beacon Sync Disconnect When a Member unit cannot receive aBeacon synchronization signal from aMaster unitTransmit IntervalTime (SiteRoaming)E201 Fan Error When the Fan can no longer spin N/AE202 Power Supply Voltage Error When the power supply voltage goeslower than the lower limit thresholdPower SupplyLower LevelE204 RX PLL Unlock When an unlocked RX PLL is detected N/AE205 TX PLL Unlock When an unlocked TX PLL is detected N/AE206 Current Consumption (HPA)ErrorWhen an error in the HPA currentconsumption is detectedFixed valueE207 Temperature (Drive Amp) Error When a Drive Amp temperature error isdetectedFixed value