15 POWER SUPPLY MONITOR / 15.3 Warning by Warning Tone202FUNC (E)/ Ver 2.0015.3 Warning by Warning ToneIf Power Supply Monitor becomes active, transmitting a warning tone warns a user that the voltage of the repeateris reduced.A warning tone is transmitted for 5 sec upon lapse of 500 ms after Power Supply Monitor becomes active.The transmitted warning tone can be configured as desired.Figure 15-1 Warning ToneNote Because the warning tone is transformed by the vocoder if a warning tone is transmitted on digital channel, thewarning tone may not be transmitted with the originally configured tone frequency, and the tone frequency mayslightly drift from the original tone frequency. The deviation for a warning tone cannot be adjusted individually. The following is the volume when a warning toneis transmitted:Analog: Applies the deviation for a test tone.Digital: The fixed value A warning tone is transmitted even if Power Supply Monitor becomes active while transmitting. However, thetransmission of a warning tone is suspended while a CW ID or CW message is being sent. In this case, thetransmission of a warning tone starts when the transmission of various signals ends. If Power Supply Monitor becomes active while a test tone is being transmitted, the test tone transmission endsand a warning tone transmission starts. No warning tone is transmitted even if Power Supply Monitor becomes active while TX Disable is enabled. Also,transmission of a warning tone ends if TX Disable becomes enabled while a warning tone is being transmitted.Configuration using KPG-D7 Configuring Warning Tone ( Edit > Optional Features > Common Page 2)