2. Server ConfigurationExpress5800/R110i-1, T110i-S, T110i Maintenance Guide 111Chapter 2 Useful Features(2/2)Item Description Default ValueAlert LevelAlert Level Specify the kind of event to alert. Error, WarningError: When "Error" is detected in each sensor type, the alert is sent to theselected address among To1 to To3.Error, Warning: When "Error" or "Warning" is detected in each sensor type, the alert is sentto the selected address among To1 to To3.Error, Warning, Information: When "Error", "Warning" or "Information" is detected in each sensor type,the alert is sent to the selected address among To1 to To3.Separate Setting: You can arbitrarily select the event and the address (To:X) to alert in eachsensor type.Alert Test Execute test by sending an alert by mail. *10 –*1: When Mail Alert is enabled, at least one address should be enabled.*2: Can be specified only when To:X is set to "Enable".*3: Up to 255 characters including alphanumeric, hyphen, underscore, period, and @ (at mark) can be used.*4: Up to 63 alphanumeric characters excluding +, ", ?, =, <, >, #, and \ can be used.*5: Up to 255 alphanumeric characters, hyphen, and period can be used for full domain name or IP address.*6: Can be specified only when SMTP Authentication is set to "Enable".*7: When SMTP Authentication is set to "Enable", at least one of the authentic method should be enabled.*8: Up to 64 alphanumeric characters can be used excluding " " blank, ",?, =, <, >, #, and \.*9: Up to 19 alphanumeric characters can be used excluding " " blank, ",?, =, <, >, #, and \.*10: Be sure to perform Alert Test after all the parameters are configured appropriately. Alert feature may fail depending onconfiguration made for network or alert receiver.