2. Server ConfigurationExpress5800/R110i-1, T110i-S, T110i Maintenance Guide116Chapter 2 Useful FeaturesMiscellaneous2.3.7The following items are available when you select Miscellaneous in BMC Configuration menu.Item Description Default ValueMiscellaneousBehavior when SELrepository is FullSpecify the behavior when SEL repository is full. *1Stop logging SEL: Any new SEL is not recorded.Clear all SEL: Erase all SEL and record a new SEL.Overwrite oldest SEL: Old SEL is overwritten with new SEL.Overwrite oldestSELPlatform Event Filter Enable or disable Platform Event Filter. *2 EnableManagementSoftwareSetting for remote management –ESMPROManagementEnable or disable BMC management by NEC ESMPRO *3 Current set valueAuthentication Key Specify the Authentication Key. *4 *5 guestRedirection Enable or disable Redirection feature. *4 *6 Enable*1: When this item is changed to/from "Overwrite oldest SEL", all log records in the SEL Repository are cleared.*2: Disabling Platform Event Filter also disables SNMP alert.*3: When BMC can be managed directly from NEC ESMPRO Manager (Ver.5.4 or later), this item must be set to "Enable". If it isset to "Enable", Authentication Key is required.*4: Can be specified only when ESMPRO Management is set to "Enable".*5: This Authentication key is used when NEC ESMPRO Manager (Ver.5.4 or later) manages the target server. Up to 16alphanumeric characters are accepted.*6: If Redirection is set to "Enable", Console Redirection port in BIOS is set to "Serial Port B" at next boot.Note If you do not use remote management feature by NEC ESMPRO, set to "Disable"for ESMPRO Management in Management Software. In this case, setting forrelevant items are hidden and unnecessary..