1. POST Error MessageExpress5800/R110i-1, T110i-S, T110i Maintenance Guide 193Chapter 3 Appendix(4/5)Error Message Description ActionC065 5th SMBus device Errordetected.An error occurred in the 5th SMBus.Contact your sales representative.C066 6th SMBus device Errordetected.An error occurred in for the 6th SMBus.C067 7th SMBus device Errordetected.An error occurred in the 7th SMBus.C068 8th SMBus device Errordetected.An error occurred in the 8th SMBus.C103 BMC core hardware failure. BMC device (chip) error Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C104 BMC IBF or OBF check failed. Accessing the BMC addressfailed.C105 BMC SEL area full. No memory to write the systemevent log. Run Offline Tools by pressing key anddelete the event logs.C10B BMC operational codecorrupted.BMC device (chip) error Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C10C BMC update firmwarecorrupted.C10D Internal Use Area of BMC FRUcorrupted.Chassis information is incorrect.C10E BMC SDR Repository empty. BMC device (chip) errorC10F IPMB signal lines do notrespond.SMC (Satellite ManagementController) failureC110 BMC FRU device failure. Failure of the SROM for storingchassis informationC111 BMC SDR Repository failure. Failure of the SROM for storingsensor data record informationC112 BMC SEL device failure. BMC device (chip) failureC113 BMC RAM test error. BMC RAM errorC114 BMC Fatal hardware error. BMC errorC115 Management controller notrespondingManagement controller does notrespond.Update the BMC firmware.C116 Private I2C bus notResponding.Private I2C bus does not respond. Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C117 BMC internal exception BMC internal error was detected.C118 BMC A/D timeout error. BMC A/D timeout error wasdetected.C119 SDR repository corrupt. BMC error or illegal SDR data wasdetected.C11A SEL corrupt. BMC error or illegal system eventlog data was detected.C11B BMC Mezzanine card is notfound.BMC Mezzanine card is notmounted.Contact your sales representative.C11C BMC Mezzanine partition isinvalid.BMC Mezzanine partition isinvalid.C11D BMC is in Forced Boot Mode. The Forced Boot Mode of BMCwas detected.Check the jumper switch on the motherboard.Unplug the power cable, wait for at least 30seconds, and then restart the server.C11E Communication with BMC wasfailed in previous boot.Communication with BMC wasfailed in previous boot.Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C11F Backup Data of BMC Mezzaninecard has corrupted.Inconsistency was found on BMCmezzanine card.Contact your sales representative.C120 BMC Runtime FW corrupted. An error occurred on BMCRuntime FW.Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C121 BMC Force Update FWcorrupted.An error occurred on BMC ForceUpdate FW.C122 BMC Configuration areacorrupted.An error occurred on BMCConfiguration area.C123 BMC eMMC inaccessible. Failed to access to BMC eMMC.C125 BMC eMMC mode error. BMC eMMC mode error.C126 BMC eMMC partitioncorrupted.An error occurred on BMC eMMCpartition.