5. TroubleshootingExpress5800/R110i-1, T110i-S, T110i Maintenance Guide 41Chapter 1 Maintenance5.12 Problem at Powering Off[?] The power is not turned off Is the suppression feature of the power switch enabled? Run BIOS Setup Utility to check the following item is set to Disabled. If it is Enabled, the power switchis not available.The menu to be confirmed: Server Power Switch Inhibit[?] The event is logged when the server is shut down forcibly (pressing power switch for at least fourseconds) Ignore this event.[?] STATUS LED turns amber after pressing POWER switch for at least four seconds to turn off the server Unplug the power cord temporarily to turn off the STATUS LED.[?] The server does not shift to Standby Power Save mode after enabling the following setting[Server]-[Power Control Configuration]-[Standby Power Save] Terminate the POST process to shift to this mode. If the POST process is cancelled, this feature maynot take effect when you use the server next time.5.13 Problem of Memory Throttling[?] The value of memory throttling remains [0%] This server does not support the memory throttling feature. The information of the memory throttlingdoes not change from [0%] in the EXPRESSSCOPE Engine 3, NEC ESMPRO Manager and ServerConfiguration Utility