1. POST Error MessageExpress5800/R110i-1, T110i-S, T110i Maintenance Guide194Chapter 3 Appendix(5/5)Error Message Description ActionC127 BMC eMMC format corrupted. A format error occurred on BMCeMMC.Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C128 BMC is in Update Mode. BMC is in update mode.C200 The error occurred duringmemory configuration check.The memory information could notbe obtained.Turn off the power and restart the server.C201 Memory Configuration changeis detected.The memory configuration haschanged since the previousstartup.When Check previous system Config isenabled in server of the BIOS settings, thismessage appears if the configuration waschanged since the previous startup. If thismessage appears even when no configurationchange has been made, contact your salesrepresentative.C202 The error occurred duringCPU configuration check.The CPU information could not beobtained.Turn off the power and restart the server.C203 CPU Configuration change isdetected.The CPU configuration haschanged since the previousstartup.When Check previous system Config isenabled in server of the BIOS settings, thismessage appears if the configuration waschanged since the previous startup. If thismessage appears even when no configurationchange has been made, contact your salesrepresentativeC300 Out-of-band setupconfiguration failureInvalid access to BMC MezzaninecardContact your sales representative.C321 System power consumption isout-of-range in BBUsOver capacity of system powercapacity.C501 Intel(R) Node Manager is inRecovery ModeThe Recovery Mode of Intel NodeManager was detected.Check the jumper switch on the motherboard.Unplug the power cable, wait for at least 30seconds, and then restart the server.C600 Internal Flash is not valid. Selected Internal Flash Memoryas an onetime booting device butunable to enable it.Turn off the power, disconnect the server from theoutlet, wait for at least 30 seconds, and restart theserver.C624 Invalid internal BIOSConfiguration Data.Internal error of BIOSConfiguration Data was detected.C625 BIOS Configuration Data SendError.An internal error was detectedduring sending BIOSConfiguration Data.C626 BIOS Configuration Data ReadError.An internal error was detectedduring reading BIOS ConfigurationData.C627 BIOS Configuration DataWrite Error.An internal error was detectedduring writing BIOS ConfigurationData.C628 System configuration datacleared by System BootOptions command.The SETUP setting was clearedby Set System Boot Options of thestandard IPMI command.Run SETUP, and then specify the necessarysettings.