(73/137)12.2 Model Name ReadThis command is used in order to read the Model Name.1) The controller requests the monitor to read Model Name.Header Message Check code DelimiterSOH-'0'-Monitor ID-'0'-'A'-'0'-'6'STX-'C'-'2'-'1'-'7'-ETX BCC CRHeaderSOH (01h): Start of Header'0' (30h): ReservedMonitor ID: Specify the Monitor ID which you want to get Model Name.Ex.) If Monitor ID is '1', specify 'A'.'0' (30h): Message sender is the controller.'A' (41h): Message type is "Command".'0'-'6'(30h, 36h): Message lengthMessageSTX (02h): Start of Message'C'-'2'-'1'-'7' (43h, 32h, 31h, 37h): Model Name commandETX (03h): End of MessageCheck codeBCC: Block Check CodeRefer to the section 4.5 “Check code” for a BCC calculation.DelimiterCR (0Dh): End of packet2) The monitor replies the model name data to the controller.Header Message Check code DelimiterSOH-'0'-'0'-Monitor ID-'B'-N-NSTX-'C'-'3'-'1'-'7'-Data(0) -Data(1)—----Data(n)-ETXBCC CRHeaderSOH (01h): Start of Header'0' (30h): Reserved'0' (30h): Message receiver is the controller.Monitor ID: Indicate a replying Monitor ID.Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.'B' (42h): Message type is "Command reply".N-N: Message lengthNote.) The maximum data length that can be returned from the monitor at a time is32bytes.MessageSTX (02h): Start of Message'C'-'3'-'1'-'7' (43h, 33h, 31h, 37h): Model Name reply CommandData(0) -Data(1)----Data(n):Model name These data are encoded to ASCII characters strings.ETX (03h): End of MessageCheck codeBCC: Block Check CodeRefer to the section 4.5 “Check code” for a BCC calculation.DelimiterCR (0Dh): End of packet