(86/137)17.2 Auto ID CompleteThis command is used in order to notify complete status of Auto ID.1) The monitor sends the controller to complete status of Auto ID.Header Message Check code DelimiterSOH-'0'-Monitor ID-'0'-'A'-'0'-'C'STX-'C'-'A'-'0'-'A'-'0'-'2'-ST-MON-ETX BCC CRHeaderSOH (01h): Start of Header'0' (30h): ReservedMonitor ID: Specify the Monitor ID of which you want to change a setting.Ex.) If Monitor ID is '1', specify 'A'.'0' (30h): Message sender is the controller.'A' (41h): Message type is "Command".'0'-'C'(30h,43h): Message length (12byte)MessageSTX (02h): Start of Message'C'-'A'-'0'-'A'-'0'-'2' (43h, 41h, 30h, 41h, 30h, 32h): Auto ID'0'-'2' (30h,32h): CompleteST: Error StatusNo Error : 00h (30h, 30h)Error : 01h (30h, 31h)MON: DETECTED MONITORS01h (30h, 31h) - 64h (36h, 34h)ETX (03h): End of MessageCheck codeBCC: Block Check CodeRefer to the section 4.5 “Check code” for a BCC calculation.DelimiterCR (0Dh): End of packet2) The controller replies to the monitor.Header Message Check code DelimiterSOH-'0'-'0'-Monitor ID-'B'-'0'-'A'STX-'C'-'B'-'0'-'A'-'0'-'2'-ST-ETX BCC CRHeaderSOH (01h): Start of Header'0' (30h): Reserved'0' (30h): Message receiver is the controller.Monitor ID: Indicate a replying Monitor ID.Ex.) When this byte is set to ‘A’, replying monitor’s ID is ‘1’.'B' (42h): Message type is "Command reply".'0'-'A'(30h,41h): Message length (10byte)MessageSTX (02h): Start of Message'C'-'B'-'0'-'A' (43h, 42h, 30h, 41h): Auto ID Reply Command'0'-'2' (30h,32h): CompleteST : Error StatusNo Error : 00h (30h, 30h) *FixedETX (03h): End of Message