4-20 Configuring Your ServerOption Parameters DescriptionBIOS Redirection Port [Disabled]Serial Port ASerial Port BSpecify whether to enable or disabledirect connections from themanagement terminal using theESMPRO Manager or hyper terminalfrom the serial port specified for thismenu item. If this menu item is enabled,the following setting menu items aredisplayed.Terminal Type [VT100+]VT-UTF8ANSISelect the terminal type.Baud Rate 96001920057600[115200]Specify the baud rate used for theinterface with the connected hardwareconsole.Data Bits 7[8]Specify the data bit width.Parity [None]EvenOddSpecify the parity bits.Stop Bits [1]2Specify the stop bit setting.Flow Control None[HardwareRTS/CTS]HardwareRTS/CTS+CDSpecify the flow control method.Continue C.R. after POST Disabled[Enabled]Specify whether to enable or disablethe continued execution of consoleredirection after the POST finishes.[ ]: Factory-set