Emergency Management Port C-15! Help Help Topics - help topics for EMP Console. Help About - provides version information.Sensor Type CodesThe Sensor Type Code Table provides information regarding:! The type of sensor generating the SEL entry! The name of the sensor! The microcontroller which initiated the SEL entry! The warning or error which initiated the SEL entry.Using the Sensor Type Code TableCompare the Sensor Type and Number message shown in the SEL viewer display(above) to the Sensor Type/Number in Verbose column in the table below. Usinginformation in the Sensor Name column in the table you can determine the physicalcomponent which generated the SEL message. The Generator ID column in the tableidentifies the microcontroller which reported the event to the SEL. Detailed informationregarding the event is available from the Event Description column in the SEL Viewer.For example, if there is a Fan #10 entry in the Sensor Type and Number column of theSEL Viewer, by looking at the Sensor type Codes table you can determine that theBaseboard Fan 1 caused this entry. The entry was reported through the BaseboardManagement Controller (BMC) on the system board.Sensor Type CodesSensor Type and Number inVerbose Sensor Name Generator IDReserved 00h BMCTemperature #17 Processor1 Temp BMCTemperature #18 Processor2 Temp* BMCTemperature #19 Baseboard Temp1 BMCTemperature #1A Baseboard Temp2 BMCVoltage # 01 Baseboard 5V BMCVoltage # 02 Baseboard 3.3V BMCVoltage # 03 Primary Processor BMCVoltage # 04 Secondary Processor* BMCVoltage # 05 Processor 2.5V BMC*Not applicable to all servers