Program 82 : Basic Hardware Setup forExtension82-04 : ASTU Initial Data SetupLevelINDescriptionUse Program 82-04 : ASTU Initial Data Setup to set the basic data of the SLT.Input DataItem No. Item Input Data Default01 Companding Method Type 0 = μ-law1 = A-law102 Ringing Frequency 0 = 25 Hz1 = 20 Hz2 = 16 Hz0 (25 Hz)03 Minimum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)04 Maximum Break Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)05 Minimum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 2 (10 ms)06 Maximum Make Time 1 ~ 255 (5 ms ~ 1275 ms) 20 (100 ms)07 Minimum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 108 (540 msec)08 Maximum Hook Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 132 (660 msec)09 Minimum Ground Flash Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)10 Minimum Off-Hook Time 1 ~ 255 (5 ms ~ 1275 ms) 21 (105 ms)11 No Detection Time after Off-Hook 1 ~ 255 (5 ms ~ 1275 ms) 60 (300 ms)12 No Detection Time after Pulse Dial Detec-tion1 ~ 255 (5 ms ~ 1275 ms) 70 (350 ms)13 Loop Disconnect Time, Reversal Time 1 ~ 255 (10 ms ~ 2550 ms) 60 (600 ms)14 Ring, Message Wait Period Time 1 ~ 255 (5 ms ~ 1275 ms) 150 (750 ms)ConditionsNoneFeature Cross ReferenceNoneISSUE 1.0SL1000/SL1100Program82Program 82 : Basic Hardware Setup for Extension2-456Downloaded from www.Manualslib.com manuals search engine