Program 82 : Basic Hardware Setup forExtension82-21 : Sensor SetupLevelINDescriptionUse Program 82-21 : Sensor Setup to setup the Sensor for SL1000/SL1100.Input DataSensor Number 1 ~ 8 (SL1000)1 ~ 6 (SL1100)Item No. Name Input Data Default01 Sensor TypeSet sensor type.0 = Close Detect1 = Open Detect002 Sensor Alarm Detect Minimum LevelSet minimum level for Alarm detection.1 ~ 255 (5 ms ~ 1275 ms) 24 (120 ms)03 Sensor Idle Detect Minimum LevelSet minimum level for Idle detection.1 ~ 255 (5 ms ~ 1275 ms) 24 (120 ms)ConditionsNoneFeature Cross ReferenceNoneISSUE 1.0 SL1000/SL1100Program82Programming Manual 2-469Downloaded from www.Manualslib.com manuals search engine