– 916 –CHAPTER 7 Maintenance CommandsTOGC: Test of Originating Connection1. Functional OutlineThis command is used to execute originating connection tests by specifying the self-trunk/station number andthe destination route/trunk number on the PCPro display.By using this command, the following is available:• Capable of observing both originating and incoming trunks, you can perform the tests even involving theTandem connection.• Different from Individual Trunk Access that uses a specific access code, this test can involve the register/sender, etc., thereby enabling the test condition the same as that in the normal connection.Also, the following shows service conditions for this test:(a) The originating side must be a station, ICT/BWT or Attendant Console.(b) Accessible trunks are REG, SND, CFT or OGT/BWT.Note: Designed trunk connection is available for ISDN trunks (Q.931a).(c) The test observation by this command is effective for approximately three minutes since the test wasinitiated.(d) When the test result is abnormal, due to a factor such as PCPro power failure, etc., the existing datafor test connection may remain on the SV8500 side. To clear the data, activate the TOGC commandagain.(e) Test results can be observed only on the trunks accommodated in the same SV8500 node even ifCALLING STN TYPE = TELN(NDM)/TELN(LDM) or CALLING RT TYPE = LGRT.(f) This connection test is restricted for FCCS trunk.(g) When testing Dterm with this command, be sure to choose My Line. Once the Dterm belongs to MyLine, it is possible to perform a test from the terminal with Sub Line.2. Parameters[When STN is selected in the TYPE selection list box]Input DataCALLING STN TYPE: Station Type of Calling PartySTN=Station NumberTELN(NDM)=Telephone Number (NDM)TELN(LDM)=Telephone Number (LDM)CALLED RT TYPE: Route Type of Called Party