Using the BayStack 450 10/100/1000 Series Switch4-10 309978-D Rev 01Table 4-3. Software Download Error CodesError code Description Corrective action2001 Download process failed to transmitpacket to other stack units.Check the stack cable connections, and thenrepeat the software download process.2002 TFTP load host failed to respond to ARPrequest.Verify that your TFTP load host is operationaland check that the connectivity between theswitch/stack and the TFTP load host is valid.2003 Received image failed CRC check. Verify that the switch software image is valid (notcorrupted) and repeat the software downloadprocess.2004 The download process has lostsynchronization with the TFTP loadhost.Verify that your TFTP load host is operational,and then repeat the software download process.2005 TFTP timeout. The software downloadhas timed out due to network congestionor the load host has stoppedresponding.Verify that your TFTP load host is operational,and then repeat the software download process.2006 File access error. Check that the file name of the software image iscorrect, and that the file protection is properlyset for access.2007 Non-data packet received from theTFTP load host.Check that the file name of the software image iscorrect.2008 Requested software image is too large. Check that the file name of the software image iscorrect, and that you are accessing theappropriate software image for your switch.2009 Received image failed CRC check. Verify that the switch software image is valid (notcorrupted) and repeat the software downloadprocess.2010 No MAC address found in EEPROM. Contact the Nortel Networks Technical SolutionsCenter.