2 - 13Chapter 2 Operation of DiagnosticDC135 HFSIDescription: Change a current status value (hereinafter referred to as the "current life") and a changeInterval value (hereinafter referred to as "spec life") of a specified consumable item.• [Clear Life]Clear a current life value of a changed HFSI component to zero.• [Change Life]Change an initial value of a spec life which refers to the time to change the HFSI component.However, there is no component whose spec life can be changed at this moment.Even if a current life exceeds a spec life, counting-up continues. However, if acounted value reached a maximum value, the maximum value is held.Procedure:1. Enter the Diag (C/E) mode, and select the [Preventive Diag DC122 SDHistory] screen in a lowerlevel using the " → " key.2. Select [Preventive Diag DC135 HFSI] in the same hierarchical level using the " ↓ " key.3. Show the applicable DC item screen [DC135 HFSI Clear Life] using the" → " key.4. Show the current life clear screen using the "FEED / SELECT" key again.• To set the chain-link No., move the cursor using the " ← " or " → " key and change a numericalvalue using the " ↑ " or " ↓ " key.When the cursor is positioned at the left end of the chain-link No., pressing the " ←" key allows you to return to the [DC135 HFSI Clear LIfe] screen in an upperhierarchical level.5. The chain-link No. is fixed by pressing the "FEED / SELECT" key. Then, "*" is marked at the rightend of the changed value.6. If there is any applicable chain-link No., show the current life using the "FEED / SELECT" key.7. If there is no applicable chain-link No., the screen below is shown.8. The current life display screen is changed into the zero clear instruction screen by pressing the "→ "key.Clear Life000-000Clear Life008-002 NG