1 - 38Chapter 1 TroubleshootingFIP1.11 EP CARTRIDGEStep Check Yes NoPossible causative parts:HVPS/MCU (PL12.1.19)EP CARTRIDGEGUIDE ASSY CRU R (PL8.1.25)1Checking EP CARTRIDGE (1)Is the EP CARTRIDGE appropriate model?Remove the EP CARTRIDGE to check the model.Go to step 2. Replace EPCARTRIDGE.2Checking EP CARTRIDGE (2)Install the EP CARTRIDGE again.Does STATUS 1-6 occur again when the power is turnedON?Go to step 3. End of work3Checking GUIDE ASSY CRU RRemove GUIDE ASSY CRU R. (RRP8.13)Is each harness continuous?Go to step 4.Replace GUIDEASSY CRU R.(RRP8.13)4Checking EP CARTRIDGE (3)Replace the EP CARTRIDGE.Does Error occur again when the power is turned ON?ReplaceHVPS/MCU.(RRP12.10)End of work