43967002TH Rev.1 224 /Oki Data CONFIDENTIAL 5. Maintenance Menu5.6.4 Scan position adjustment5.6.4.1 Side registration adjustmentThe separate setting items are prepared for FBS, ADF (front side) and ADF (back side)independently.Setting for FBSValue Default Reference value Display condition+25 0 -25(+5.29mm 0-5.29mm)-10(-2.117mm)±1.2mm NonePerform adjustment so that the scan start position in the horizontal scanning direction duringFBS scanning stays within the reference value.Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.When a value is added in the negative (-) direction, the scan image on a PC moves to the right.When a value is added in the positive (+) direction, the scan image on a PC moves to the left.Setting for ADF (front side)Value Default Reference value Display condition+25 0 -25(+5.29mm 0-5.29mm)+1(+0.2117mm)±1.8mm NonePerform adjustment so that the scan start position in the horizontal scanning direction duringADF front side scanning stays within the reference value.Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.When a value is added in the negative (-) direction, the scan image on a PC moves to the left.When a value is added in the positive (+) direction, the scan image on a PC moves to the right.Setting for ADF (rear side)Value Default Reference value Display condition+25 0 -25(+5.29mm 0-5.29mm)+18(+3.8106mm)±2.3mm NonePerform adjustment so that the scan start position in the horizontal scanning direction duringADF rear side scanning stays within the reference value.Adjustment in increment of 1 item (5/600 dpi = 0.2117 mm) is possible in this setting.When a value is added in the negative (-) direction, the scan image on a PC moves to the left.When a value is added in the positive (+) direction, the scan image on a PC moves to the right.5.6.4.2 Top end position adjustmentThe separate setting items are prepared for FBS, ADF (front side) and ADF (back side)independently.Setting for FBSValue Default Reference value Display condition+31 0 -31(+4.36mm 0-4.36mm)+8(+1.1264mm)±1.2mm NonePerform adjustment so that the scan start position in the vertical scanning direction during FBSscanning stays within the reference value.If shade is scanned at the top end of a document, make adjustment in the positive direction. Ifdeficiency occurs at the top end of a document, make adjustment in the negative direction.Adjustment in increment of 1 item (0.1408 mm) is possible in this setting.When a value is added in the negative (-) direction, the scan image on a PC moves down.When a value is added in the positive (+) direction, the scan image on a PC moves up.