Miscellaneous functionsKW2M-A/X User's Manual 536.2.8 Power alarmWhen the measured value exceeds the setting for instantaneous electric power (active, reactive,apparent, active (export), reactive (export)), pulse output turns on in order to notice.When the measured value falls below, the output turns off.6.2.9 Other alarmsOutput turns on or off according to each alarm setting.PF alarm, over frequency alarm, under frequency alarm, voltage harmonics alarm, current harmonicsalarm、voltage THD alarm, current THD alarm, voltage unbalancing alarm, current unbalancing alarm,power demand alarm, current demand alarm6.2.10 Output depends on count valueSet a preset value and the pulse output turns on when the count value has reached the preset value.Refer to 6.3 Counter function for details.6.2.11 Level outputIt turns on or off the output by writing 0 (OFF) or 1 (ON) to the data register allocated to each output(OUT1: DT50294, OUT2: DT50295) for communication with an external device.6.3 Counter function●Operation modeMaintain output hold count HOLD[Output] OFF ON[Counting] possible[Addition] 0 1 2 3 ・・・ n-2 n-1 n n+1 n+2 n+3n: Preset value(1) Output turns on when preset value “n” is reached. The output is held until it is reset. The devicekeeps on counting even after “n” has been reached.(2) The counter reverts to “0” after it has counted to the end of the valid range, but output control isstill maintained. However, the output turns OFF if the count value or the preset value arechanged.●Change the Preset ValueIt is possible to change the preset value even during counting. However, please note the followingpoints.◇When the pre-scale value is “1.000” (PSCL=1.000).(1) If the preset value is changed to a value lower than the count value, counting will continue until itreaches the end of the valid range, returns to “0” and then reaches the new preset value.(2) If the preset value is changed to “0”, the counter will not begin counting at “0” right away. Instead,counting will continue until it reaches the end of the valid range and then it will start countingfrom “0”.(3) When the count value is fixed, output is changed according to the changing of preset value asbelow. If the preset value is changed to a value lower than or equal to the count value, the output is ON.(Count value ≥ Preset value) If the preset value is changed to a value higher than the count value, the output is OFF.(Count value < Preset value)◇When the pre-scale is not “1.000”. (PSCL≠1.000)Even if the preset value is changed after counting to the end of the valid range, the output is notchanged.