4.6 CO Line ProgrammingCPC Signal Detection Incoming Set405System Programming 4-93Description Assigns the expected minimum duration of the CPC Signal onincoming outside calls. If this is programmed, the systemdisconnects the line when the CPC Signal is detected.Selection • CO line number:KX-TD816 – 01 through 08, ( =all CO lines)KX-TD1232 – 01 through 24, ( =all CO lines)• Time (milliseconds): Disable (no detection) / 02 through 75 (5 8is the actual time)(See the table on the following page.)Default All CO lines – 44 (352 ms)Programming 1. Enter 405.Display : CPC Detection2. Press NEXT.Display: CO Line NO?–>3. Enter a CO line number.To enter CO line number 01, you can also press NEXT.Display example: CO01:Disable4. Enter the time, or press CLEAR to select “Disable.”To change the current entry, press CLEAR and the new time.5. Press STORE.6. To program another CO line, press NEXT or PREV, orSELECT and the desired CO line number.7. Repeat steps 4 through 6.8. Press END.Conditions • In the case of KX-TD1232, CO01 through CO12 are for the MasterSystem and CO13 through CO24 are for the Slave, if available.• To assign all CO lines to one selection, press the key at step 3. Inthis case, the display shows the contents programmed for CO01.• You may disable CPC Signal Detection for a CO line.• Program [415] “CPC Signal Detection Outgoing Set” is used toprogram CPC Signal Detection for outgoing outside calls.Feature References Section 3, Features,Calling Party Control (CPC) Signal Detection