4.6 CO Line ProgrammingCPC Signal Detection Outgoing Set4154-102 System ProgrammingDescription Enables or disables CPC Signal Detection during the time betweenthe originated outside call and the established outside call. If this isenabled, the system disconnects the line with the time set inprogram [405] “CPC Signal Detection Incoming Set” when CPCSignal is detected.Selection • CO line number:KX-TD816 – 01 through 08, ( =all CO lines)KX-TD1232 – 01 through 24, ( =all CO lines)• Enable (detection) / Disable (no detection)Default DisableProgramming 1. Enter 415.Display: CPC Outgoing Asn2. Press NEXT.Display: CO Line NO?–>3. Enter a CO line number.To enter CO line number 01, you can also press NEXT.Display example: CO01:Disable4. Keep pressing SELECT until the desired selection isdisplayed.5. Press STORE.6. To program another CO line, press NEXT or PREV, orSELECT and the desired CO line number.7. Repeat steps 4 through 6.8. Press END.Conditions • Some central offices (CO) may send CPC-like signals during thedialling sequence and an attempt to make a call may be terminated. Ifyour CO is such a type, select “Disable.”• Program [405] “CPC Signal Detection Incoming Set” is used to setCPC Signal Detection Time.• In the case of KX-TD1232, CO01 through CO12 are for the MasterSystem and CO13 through CO24 are for the Slave, if available.• To assign all CO lines to one selection, press the key at step 3. Inthis case, the display shows the contents programmed for CO01.Feature References Section 3, Features,Calling Party Control (CPC) Signal Detection