- 11 -- 10 -InstallationEnvironmental conditionItem ConditionAmbienttemperatureBrushless motor –10 ℃ to 40 ℃ (free from freezing) *1Brushless amplifier0 ℃ to 50 ℃ (free from freezing) *1Digital key pad(Option)Ambient humidity 20% to 85% RH (free from condensation)Storage temperature At normal temperature and normal humidity *2ProtectionstructureBrushless motorIP65(Excluding shaft pass-through section and lead wire connector)• This motor meets test requirements specified in ENstandards (EN60529 and EN60034-5). This motorcannot be used for an application that requires longterm waterproof performance, such as the case wherethe motor is always washed with water.Brushless amplifierEquivalent to IP20Digital key pad(Option)Vibration Not greater than 4.9 m/s 2 (10 to 60 Hz)Altitude Not greater than 1000 m*1 Ambient temperature is measured at a distance of 5 cm from the product.*2 Temperature which is acceptable for a short time, such as during transportation,is –20 ℃ to 60 ℃ (free from freezing).Installation of brushless motor• Oil and water protection(1) Direct down the lead of cable as far as possible.(2) Avoid use in such an environment where the motor is always exposed to oil and water.(3) Avoid use with cable immersed in oil or water.• Stress to cable(1) Make sure that stress is not applied to the lead or connection of cable due to bendingor dead weight.(2) In installation where the motor moves, fix the cable of motor, and house the extensioncable connected to it in the cable bear to reduce stress by bending as small aspossible.(3) Allow the bending radius of cable as large as possible.Installation of brushless amplifierThe amplifier is a vertical placement type. Install it vertically and provide at least10 cm space around it for ventilation.(1) When installing with screwDetermine the fastening torque of the fixing screwbased on the strength of the screw and material ofthe mounting surface, to ensure secure and safeinstallation.Example) To install to steel plate with steel screw (M4):1.35 to 1.65 N・m(2) When installing to DIN railThe DIN rail mounting unit is available as option.For details, refer to P.106.VerticalLocation offixing screwLocation offixing screwCautions for Proper Use(1) Because the control circuit is sensitive to temperature and impact, read this instructionmanual carefully for proper installation.(2) The brushless amplifier switches the power element at a high speed to control themotor. When the motor runs, leaking current will increase, which may activate theleakage breaker. If this is the case, use a leakage breaker provided with measureagainst high frequency for inverter.Installation/ Caution