Mounting HLR Mounting Instruction34 192-510201N1 HLR 2019-04 Place the OSP-E20BV z-axis on the mounting plate and fasten it with thesupplied screws (see Figure 8: Pos. 6) and the required tightening torque (pleaserefer to Table 8).HLR080Tightening torque of mounting plates (Figure 8, Pos.4)Screw type [ISO 4762] - M6x30 – A2-70Tightening torque [Nm] 8.8Tightening torque of mounting plates (Figure 8, Pos.5)Screw type [ISO 4762] - M5x20 – A2-70Tightening torque [Nm] 5.0Tightening torque OSP-E20BV (Figure 8, Pos.6)Screw type [ISO 4762] - M6x20 – A2-70Tightening torque [Nm] 6.4Table 8: Tightening torques of mounting plates for OSAP 20-73.7 Assembly of accessoriesIn this chapter you can read about:Sensors ........................................................................................................................... 34External end stops ........................................................................................................... 363.7.1. SensorsAll HLR linear actuators have a permanent magnet integrated in the carriage onboth sides of the support profile. It activates the sensors which are mounted in thespecial mounting grooves on the support profile of the cylinder. For sensorrecommended please refer to the HLR catalogue.Please observe the Operating Instructions of the manufacturer whencommissioning the sensors.Sensor mounting Remove the groove cover strips (Figure 9, Pos. 1) from the sensor groove (onlyfor HLR080) of the support profile. Insert the sensor into the sensor groove for HLR080 (Figure 9, Pos. 1) and intothe T-slot (Figure 9), Pos.2) for HLR070 and push the sensor to the desiredposition (position of the permanent magnet in the carriage profile (see Figure 9).The position of the permanent magnet is not visible from the outside. Connect thesensor on the power supply according to the operating instructions and move it inthe support profile along the carriage until the sensor is damped. This allows youto determine on which side of the carriage the permanent magnet is located. Tighten the fixing screws on the limit switches slightly and lead the cable alongthe profile groove. You can use the formerly removed protective covers (for HLR080 only) in order tofix the sensor cables. Please cut the covers to the desired length. A pair ofscissors may be used. Insert the cover strips over the sensor cable in the grooveagain. Insert the cables into the grooves of the plastic covers and push the coverinto the groove together with the cable. Connect the sensors to the controller according to the description in the supplier’smanual.