Maintenance and service HLR Mounting Instruction40 192-510201N1 HLR 2019-045.2 Maintenance schedule and replacement intervalsMaintenance scheduleWhen What Action / elimination ChapterForcommissioningLinear actuatorVisually inspect linear actuator for damages andfree movement of carriage. In case of stiffness,contact Parker.Guiding unit At downtimes ≥ 1 year: Relubricate (Manufacturingdate- please refer to the type plate).Description (seepage 41)1 x half-yearly Linear actuatorVisually inspect and clean carriage, lip seal, coverstrip, deflection station, connection shaft and driveunit.Lightly wet the steel strip over its entire length withPTFE spray (Teflon spray).Clean daily when heavily soiled.Once a year whenreaching lubricatingintervalsGuiding unit Relubricate Description (seepage 41)Lip seal of carriagelidVisual inspection for dirt and wear. Celan whenheavily soiled. Replace if worn.Description (seepage 49)Steel strip coverVisual inspection for damage and wear. Cleanwhen soild and lightly wet over its entire length withPTFE spray (Teflon spray). Clean daily whenheavily soiled.Replace if damaged or worn.Description (seepage 43)Toothed beltCheck pre-tension and wear. Visually assess thewear of the toothed belt. If it is too high, exchangethe toothed belt.Description (seepage 45)Table 10: Maintenance planReplacement interval:What Mileage Action EliminationLip seal 15.000 to be replaced Description (seepage 49)Steel strip deflection 15,000 to be replaced Description (seepage 50)Steel strip sliding rods 15,000 to be replacedSteel strip coverAccording to life cycleof the lLinear actuator*Replace linearactuatorToothed beltGuiding unitBall bearingTable 11: Replacement intervals* Life cycle of guiding systems depends on application, see calculation HLRCatalogue.