MIB Traps Appendix CRADWIN 5000 HPMP User Manual Release 3.2.00 C-29MIB TrapsGeneralEach ODU can be configured with up to 10 different trap destinations. When the link is oper-ational, each ODU sends traps originating from both Site A and Site B.The source IP address of the trap is the sending ODU. The trap originator can be identified bythe trap Community string or by the trap description text.Each trap contains a trap description and additional relevant information such as alarm sever-ity, interface index, time stamp and additional parameters.winlink1000HsuAirRemoteCompressedStatic RO Holds all the configuration data of the HBS in acompressed format. Helps the NMS to get inforegarding new Unregistered links. FieldsIncluded: Location (32 bytes) IP address (8bytes in hexa) Subnet mask (8 bytes in hexa)HBS Antenna type (1 byte) HBS Agent Version(4 bytes)winlink1000HsuServiceCommandStr RW Ability to perform special command in the HSU.Format (string): Operation Param1 Param2 ....|ParamN.winlink1000GeneralTrapDescription 1.3.6.1.4.1.4458.1000.100.1 DisplayString RO Trap's Description. Used for Trap parameters.winlink1000GeneralTrapSeverity 1.3.6.1.4.1.4458.1000.100.2 Integer RO Trap's Severity. Used for Trap parameters.winlink1000GeneralCookie 1.3.6.1.4.1.4458.1000.100.3 DisplayString RW Reserved for the Manager application providedwith the product used for saving user preferencesaffecting ODU operation.winlink1000GeneralEcChangesCounter 1.3.6.1.4.1.4458.1000.100.4 Integer RO This counter is initialized to 0 after a device resetand is incremented upon each element constantwrite operation via SNMP or Telnet.winlink1000GeneralTelnetSupport 1.3.6.1.4.1.4458.1000.100.5 Integer RW Enable/Disable Telnet protocol.winlink1000GeneralWISupport 1.3.6.1.4.1.4458.1000.100.6 Integer RW Enable/Disable Web Interface protocol.Mandatory Disabled - No option to enable thefeature. Mandatory Enabled - No option todisable the feature.Table C-2: Private MIB Parameters (Sheet 25 of 25)Name OID TypeAccessDescription