Chapter 8: Device Management172e. Username Field - Enter the username parameter that will beused in the URL. For example username=admin, whereusername is the username field.f. Password Field - Enter the password parameter that will be usedin the URL. For example password=raritan, where password isthe password field.10. Click OK.To change the active status of a KVM switch port or URL:1. Choose Device Settings > Port Configuration. The Port Configurationpage opens.2. Click the Port Name of the target server you want to rename. ThePort Page opens.3. Deselect the Active checkbox next to the KVM switch target port orURL to change its active status.4. Click OK.Configuring Rack PDU (Power Strip) TargetsThe KX II allows you to connect rack PDUs (power strips) to KX II ports.KX II rack PDU configuration is done from the KX II Port Configurationpage.Connecting a Rack PDURaritan PX series rack PDUs (power strips) are connected to theDominion device using the D2CIM-PWR CIM.To connect the rack PDU:1. Connect the male RJ-45 of the D2CIM-PWR to the female RJ-45connector on the serial port of the rack PDU.2. Connect the female RJ-45 connector of the D2CIM-PWR to any ofthe available female system port connectors on the KX II using astraight through Cat5 cable.3. Attach an AC power cord to the target server and an available rackPDU outlet.4. Connect the rack PDU to an AC power source.