City Series CC40EPV | 59installationLP Conversion Instructions920-040 02.13.191CITY SERIESCONVERSION FROM NG TO LPCV40E/ CB40E/CC40E-11 using SIT 885 NOVA Gas ValveCaution: The gas supply shall be shut off prior to disconnecting theelectrical power, before proceeding with the conversion.Always let the appliance cool to room temperature before servicing.1. Remove the outer panels and safety glass — see manual.2. Remove inner ceramic glass — see manual.3. Remove inner panels — see manual.4. Remove all media installed on burner (glass, logs or stones, etc).5. Disconnect the Cable coming from the Pressure Regulator Motor.6. If unable to access this Cable - undo 2 screws securing the IFC Boardand slide out of unit to access cable.WARNINGThis conversion kit shall be installed by a qualifiedservice agency in accordance with the manufac-turer’s instructions and all applicable codes andrequirements of the authority having jurisdiction.If these instructions is not followed exactly, a fire,explosion or production of carbon monoxide mayresult causing property damage, personal injuryor loss of life. The qualified service agency is re-sponsible for the proper installation of this kit. Theinstallation is not proper and complete until theoperation of the converted appliance is checked asspecified in the manufacturer’s instructions sup-plied with the kit.THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTERIF IN DOUBT DO NOT DO THIS CONVERSION!Cable from motorConversion Kit 657-977 includes:1 911-191 Stepper Motor LP for 885 SIT1 904-947 Orifice #531 910-037 Pilot Orifice #301 918-590 Decal - Conversion to LP1 908-528 Label Propane1 904-529 5/32" long Allen Key1 920-040 Instruction Sheet7. Remove and discard 2 Pressure regulator screws (A)using a (T20 or slotscrewdriver,) Pressure Regulator (B) and Spring and Diaphragm (C)(see below).8. Ensure the rubber gasket, which is prefitted as part of the Assembly,is properly positioned. Install the new Pressure Regulator using the 2xM4 x .7 screws supplied. Tighten the screws to 25lb-in. In the event thatthe screw threads are cross threaded or stripped, replace the valve as-sembly.Install the enclosed propane identification label to the valve body where itcan be easily seen.Pressureregulatorscrews9. Re-attach the Pressure Regulator wire (disconnected in Step 6), and re-situate the IFC, secure the screws that fasten the IFC Mounting Brackets.10. Remove pilot hood by lifting up and off.