City Series CC40EPV | 61installation919-742 11.07.16CC40RE/CC40LE INNER PANELS1. Install inner lower base panel.2. Install panel clips into the slots at the top of the back panel as shown.4. Install panel clip into the slots at the top of theside panel as shown.3. Manoeuvre in back panel to the back wall of the unit—secure in placewith 2 panel clips and 2 screws.5. Manoeuvre in side panel to the side wall of the unit—secure in placewith 1 panel clips and 1 screws.CC40RE/CC40LE OUTER PANELSOuter side panel installOuter base panel installNote: Install inner safety glass prior to installation of outer panels-seeinstructions in manual1. Attach Regency logo to the right hand side of outer front panel. Themagnets will be positioned under the outer front base panel to securethe logo. The logo should be about 3 inches from the right hand cornerof the outer base. Install outer front and side base panel.2. Install side panels - the side panels are secured in place by existingmagnets in the unit.The CC40RE/CC40LE can be equipped with optional steel inner panels.There are 4 outer panels and 3 inner panels.NOTE: CC40RE shown in diagrams—CC40LE panels install in the sameorder. Installed panels for the CC40LE will appear as mirror images ofdiagrams shown below.Turn off unit and allow to cool to room temperature. Remove the safetyglass and firebox glass — see manual for instructions.3. Install outer safety glass.4. Reverse steps to remove panels.6. Reverse steps to remove panels.tooltipPanel ClipsPanel ClipLocation ofRegency Logotooltip1CITY SERIESInner Panels - CC40LE/CC40REOuter Panels - CC40LE/CC40RECC40LE/CC40RE Painted Panel Installation