38 Regency® P33E-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION6) Identify wires in the GT remote wiring harness.(see wiring diagram.)7) Connect the TPTH and TH wires - green to green and white towhite as shown below. See attached wiring diagram for details.8) Plug in receiver DC supply wire - as shown below.9) Install 4 - AA batteries into the receiver, ensure correct polarity.10) Plug receiver wires into the back of the receiver and bundle wireswith the wire clip as shown below.11) Install the heat shield to the receiver with two screws and attach tothe fl oor of the unit with a velcro pad.12) Reverse steps 5 and 4.13) Match the remote control to the receiver - see remote controlinstructions.14) Reverse steps 2 and 1.15) Check to ensure there are no gas leaks.4) Remove DFC (digital firebox control box) from the fl oor of the unit.5) Disconnect wire harness, ground wire and spark wire from DFC.See attached wiring diagram for details.1) Shut off the gas supply and disconnect all power to the unit.2) Remove the louvers, bay door or faceplate if installed.3) Disconnect battery pack - located on the floor of the unit, as shownbelow and discard.TPTH(white) TH(green)Heat ShieldWire ClipGT REMOTE INSTALLATION