47SettingPower managementF o r r e d u c i n g p o w e r c o n s u m p t i o n a s w e l l a smaintaining the lamp life, the Power managementfunction turns off the projection lamp when theprojector is not used for a certain period.When the input signal is interrupted and no button ispressed for more than 30 seconds, the timer displaywith "No signal" appears. The countdown starts to turnoff the lamp.Select one of the operations:Ready. . . . . . . . When the lamp has been fullycooled down, the POWER indicatorchanges to green blinking. In thiscondition, the projection lampis turned on if the input signal isreconnected or any button on thetop control or remote control ispressed.Shut down . . . . When the lamp has been fullycooled down, the power is turnedoff.Off . . . . . . . . . . Power management function is off.Then set the countdown timer with the Point 7 8buttons.Time left before Lamp is off.Press the SELECT buttonat Power management andthis box appears. Chooseone of three settings withthe Point 7 8 buttons, andgo to the timer with thePoint ed buttons and settime with the Point 7 8buttons.Power managementTerminalThe COMPUTER IN /MONITOR OUT terminal on theback of the projector is switchable for computer inputor monitor output. (See page 9) Select Computer orMonitor Out with the Point 7 8 buttons.Computer . . . . . . computer inputMonitor Out . . . . . . monitor outTerminal function is not available when selectingComputer to the input source. Change the inputsource to the others (Computer1 or Video) so that theTerminal function will be available. (p.5, 35, 36)✔ Note:Factory default is " Ready, 5 min".