PLC-XW200/250 Expand Serial Command Functional Specifications16 / 648.4.5 CF_SHARP CommandCommand “CF_SHARP_%1”[CR]%1“000~015” ---------------- Directly select Sharpness setting value“UP” ------------------------ Current Sharpness setting value + 1“DN” ------------------------ Current Sharpness setting value - 1DetailsSet Sharpness value of user controlProjector does not save the value set with this command so that it returns itsoriginal when projector turning into Stanby mode or ALL is OFF. (The value is heldin Suspend mode.)This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.4.6 CF_GAMMA CommandCommand “CF_GAMMA_%1”[CR]%1“000~015” ---------------- Directly set Gamma setting value“UP” ------------------------ Current Gamma setting value + 1“DN” ------------------------ Current Gamma setting value – 1DetailsSet Gamma value of user controlProjector does not save the value set with this command so that it returns itsoriginal when projector turning into Stanby mode or ALL is OFF. (The value is heldin Suspend mode.)This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.4.7 CF_WBAL - CommandCommand “CF_WBAL-%1_%2”[CR]%1“ ” --------------------- Red“ ” --------------------- Green“ ” --------------------- Blue%2“000~063” ----------- Directly select Color value specified by White Balance%1“UP” ------------------- Current Color value set by White Balance%1 + 1“DN” ------------------- Current Color value set by White Balance%1 - 1DetailsSet Color value set by White Balance%1 of user controlProjector does not save the value set with this command so that it returns itsoriginal when projector turning into Stanby mode or ALL is OFF. (The value is heldin Suspend mode.)This command is available in normal Power ON status.Response Acceptable “000”[CR]Unacceptable “Error Code”[CR]8.4.8 CF_COLTEMP CommandCommand “CF_COLTEMP_%1”[CR]%1“000” ------ Xlow“001” ------ Low“002” ------ Mid“003” ------ HighDetailsSet Color Temperature. (Available only in the normal Power ON status)The value set by this command will not be saved to the projector. Therefore, whenturning into Stanby-mode or ALL is OFF, the value returns to original setting. (Thevalue is held in Suspend mode.)This command is available in normal Power ON status.