PLC-XW200/250 Expand Serial Command Functional Specifications49 / 649.7.7 CR_SYSLIST CommandCommand “CR_SYSLIST”[CR]Details Get selectable System titlesResponseAcceptable “000_%1_%2_..._%x” [CR]%1- When Input is PC-Analog“XGA1” ------------ XGA1is selectable“1080I ” ----------- 1080i is selectableProjector does not return Auto,Mode1-5When there is no signal, it returns Error Code “101”-When Input is Y,Pb/Cb,Pr/CrReturns all the System titles on Menu including Auto“AUTO” ------------ Auto is selectable“1080I” ------------ 1080i is selectable“1035I” ------------ 1035i is selectable“575I” ------------ 575i is selectable“480I” ------------ 480i is selectableProjector does not return Error Code “101” evev if there is nosignal.-When Input is Video, S-VideoReturns all the System titles on Menu including Auto“AUTO” ---------Auto is selectable“PAL” ------------ PAL is selectable“SECAM” ------ SECAM is selectable“PAL-N” --------- SECAM is selectableProjector does not return Error Code “101” evev if there is nosignal.Unacceptable ““Error Code”[CR]9.7.8 CR_MODELIST CommandCommand “CR_MODELIST”[CR]Details Get selectable Mode titlesResponseAcceptable “000_%1_%2_..._%x” [CR]%1%2:%xReturns Error code “101” when Input is other than PC-AnalogReturns Error code “101” when Input is PC-Analog but no signalWhen Input is PC-Analog and signal is found, returns selectableMode among Mode1 – 5“MODE1”::“MODE5Unacceptable “Error Code”[CR]