01/024-88 8825/8830 PrinterREP 10.1Repairs and AdjustmentsREP 10.1 Heat RodParts List on PL 10.2WARNINGSwitch off the Main Power Switch. Disconnect the Power Cord. Allow the Fuser Assem-bly to cool before the procedure is performed.Removal1. Remove the Stripper Finger Assembly.2. Perform the Xerographic Module procedure (REP 9.1) through Step 11. This will leave theXerographic Module at the Service Position, handles installed, and the Drum Assemblyremoved.NOTE: In the following steps, “Left” and “Right” describe machine locations as observed whenyou are facing the Xerographic Module at the left side of the Printer.3. (Figure 1): Disconnect the Heat Rod (Right Side).Figure 1 Removing the Bracket and Grommet (Right Side)2Disconnect the con-nector and straightenthe Heat Rod Wire1Remove the HeatRodWire from the clamp3Remove thescrew4Remove the bracketfrom the grommet5Remove the grommetfrom the Heat RodWireGrommet