01/024-938825/8830 Printer REP 10.7, REP 10.8Repairs and AdjustmentsREP 10.7 Web Oiler AssemblyParts List on PL 9.6WARNINGSwitch off the Main Power Switch. Disconnect the Power Cord.Removal1. Loosen the screws and open the Rear Door.2. Raise and latch the Top Cover.3. Ensure that there is a clean, flat surface on which to place the Web Oiler Assembly after itis removed.4. (Figure 1): Remove the Web Oiler Assembly and place it top down, resting on the han-dles, on a flat surface.Replacement1. At reinstallation, engage the rear lip of the Web Oiler Housing over the metal bracket ofthe Xerographic Module.2. After completing the reassembly, enter diagnostics and perform one of the followingactions.a. If a new Web Oiler has been installed, initialize the Web Oiler using [1030].b. If the old Web Oiler is still in the assembly, remove the slack in the web by running[1033] until the display shows the following: Count = 001Figure 1 Removing the Web Oiler AssemblyREP 10.8 Stripper FingersParts List on PL 10.4WARNINGSwitch off the Main Power Switch. Disconnect the Power Cord. Allow the Fuser Assem-bly to cool before the procedure is performed.Removal1. Remove the Stripper Finger Assembly.2. (Figure 1): Remove the Stripper Fingers.Figure 1 Removing the Stripper Fingers1Loosen the twothumbscrews3Holding the handles, rotate therear upward. Lift it and remove.2Disconnect P/J4Stripper FingerTab1Remove theStripper Fingerwhile pushingthe tab