01/023-20 8825/8830 PrinterPQ 22Print QualityPQ 22 OffsettingTable 1 Offsetting Symptom / CheckSymptom/ checkOffsetting is the result of toneradhering to the Fuser HeatRoll and transferring to subse-quent prints.Probable Cause Corrective Action1. There is insufficient fuseroil on the Heat Roll.1A. Check/replace the WebOiler ( REP 10.7).1B. Check/adjust oil dispenserate [10-32].2. The fuser temperature isout of specification.2. Check Fuser Temperature( ADJ 10.1).3. The Fabric Guide is notcontacting the Fuser Heat Rolluniformly.3. Check / replace the FabricGuide ( REP 8.9) and Pres-sure Plates ( REP 8.5).4. Media is damp. 4A. Ensure that the media isstored correctly.4B. Refer to BSD 7.1 andBSD 7.3 to check for correctoperation of the paper heat-ers.5. Damaged or contaminatedheat roll5. Clean or replace the HeatRoll ( REP 10.2).