01/022-10 8825/8830 PrinterLL-90 Overtoned Fault RAPStatus Indicator RAPsLL-90 Overtoned Fault RAPNOTE: Go to BSD 9.7 while using this RAP.The status code LL-90 is displayed when the logic detects that the toner concentration is signif-icantly greater than the Control Point value.The Toner Control System is designed to maintain the Toner Concentration within an accept-able operating range. The Control Point operating range is from 5.2 VDC to 6.0 VDC. TheToner Sensor continuously senses the Toner Concentration. A change in the Toner Concentra-tion results in a corresponding change of the Sensor signal. As the toner concentrationincreases, the Toner Sensor signal voltage decreases. The logic monitors the Sensor signal.LL-90 indicates that the logic detected that the toner concentration increased greater than theallowable limit.The problem may occur if there is a problem with the toner dispensing or the developer mixingsystems.Initial Actions• Clean the Pressure Equalizing Tubes with a vacuum cleaner in order to remove tonerfrom inside the tubes. Clean the Augers and Magnetic Roll• Examine the Developer Housing and check for a large amount of toner in the area of theToner Dispenser.• Ensure that the printer is level.• Ensure that the Toner Cartridge is not damaged and that the seal is secured to the Car-tridge in the correct location.• Check that all the connectors between the Toner Sensor, A22Q1, and the Main PWB, A2,are seated correctly.• (Figure 1): Ensure that the Developer Housing Auger and Drive Gears are not damagedand are installed correctly.Figure 1 Developer Housing and Auger Drive GearsEnsure that the Rear Auger Drive Gear is positioned with the flange as shown.Ensure that the Developer Housing Drive Gear is positioned with the flange asshown.Ensure that the Front Auger Drive Gear is captured in position by the Rear AugerDrive Gear Flange and the Developer Housing Drive Gear flange.DeveloperHousing DriveGearFlangeFlangeCartridge DriveMotor removedfor clarityRear AugerDrive GearFront Auger Drive Gear