TroubleshootingWorkCentre 6505 Color Laser Multifunction PrinterUser Guide184Control Panel MessagesThis section includes:• Supply Status Messages on page 184• Error Messages on page 185The printer uses control panel messages to indicate printer status, errors, and to provide instructions.Supply Status MessagesStatus messages tell you about the status of the printer and its supplies.Note: Xxx indicates one of the following: the Yellow Toner (Y), Cyan Toner (C), Magenta Toner (M),Black Toner (K), a tray, or fuser. NNN indicates a numeric value.Code/Message Condition/Reason/SolutionReplace Fuser010-351Time to replace the fuser.Replace the old fuser with a new one and then restart the printer.Insert Fuser010-317The fuser is not installed or it is incorrectly installed.Install the fuser and then restart the printer.Replace Imaging Unit It is time to replace the imaging unit.Replace the imaging unit. For details, see the Imaging Unit instructionsheet that came in the documentation packet with your printer.Insert Imaging Unit The imaging unit is not installed.Install the imaging unit. For details, see the Imaging Unit instruction sheetthat came in the documentation packet with your printer.Insert Xxx Cartridge The Xxx toner cartridge is not installed correctly or is not installed. Installthe toner cartridge.Replace Xxx Cartridge The toner cartridge is empty.Replace the old toner cartridge with a new one.Invalid Xxx The wrong toner cartridge is installed or the toner cartridge is not seatedcorrectly. Reseat the toner cartridge or replace the cartridge with one thatmeets specifications for your printer. The region of your printer is listed onthe Configuration Page in the General section. For details on printing theConfiguration Page, see Configuration Page on page 24.Non-Xerox® Toner The printer is in the custom toner mode. This message means a non-Xerox ® toner is installed. You could experience a decrease is print quality asa result.Low DensityXxx CartridgeToner is not distributed evenly in the specified cartridge. Remove and shakethe cartridge, then reinstall it.