3.2 Function Modules3.2.10 Maintenance Monitoring3-98ļ Select the data update period.3. Click the Allocate Axis Button.The Axis Selection Dialog Box will be displayed.Rush current preven-tion circuit lifetimeThe maintenance period of the inrush preventionrelay is displayed as a percentage. When usageis first started, 100% is displayed. The percent-age become smaller as the operating timeincreases. When 0% is displayed, it is time toconsider replacement.SERVO-PACK 1 0.01%Dynamic brake circuitlifetimeThe maintenance period of the IGBT is dis-played as a percentage. When usage is firststarted, 100% is displayed. The percentagebecome smaller as the operating time increases.When 0% is displayed, it is time to considerreplacement.SERVO-PACK 1 0.01%Controller installationenvironmentThe temperature environment load status in theController is displayed.Control-ler 1 1%You can select the same monitor item for more than one group.Selection MeaningFrequent The data is updated approximately once every second.Regular The data is updated approximately once every 10 seconds.Infrequent The data is updated approximately once every 100 seconds.The data update periods are guidelines. The update periods may be increased depending on thenumber of monitored axes.Continued from previous page.Selection ContentsMoni-toredDeviceNum-ber ofWordsUnitInformationNote