4.15 Method 1: Copy One Subtask Job and Create Another Job4-284.15.3 Correcting Positional DislocationIn the job after mirror shift, a position may be dislocated due to the installation error. In thiscase, all steps should be corrected by the same shift amount. For this operation, the parallelshift job conversion function is used. Setting the Items for ConversionOperation Explanation1 Select {JOB} under the mainmenu.2 Select {JOB}. The JOB CONTENT window appears.3 Select {UTILITY} under thepull-down menu.4 Select {PARALLEL SHIFTJOB}.The PARALLEL SHIFT JOB window appears.5 Specify the conversion items. Specify the following items.SOURCE JOBSelects the job before conversion. The job which is shown inthe JOB CONTENT window is set initially. To change the job,perform the following procedure.Move the cursor to the job name and press [SELECT]. TheJOB LIST window appears. Select the desired job.STEP SECTION (Start Step End Step)Specifies the step section of the source job. All the steps areset initially. If there is no steps in the source job, “***” is dis-played. To change the section, perform the following proce-dure.Move the cursor to the step section indication and press[SELECT]. The input buffer line appears. Input the step numberand press [ENTER].PARALLEL SHIFT JOBSOURCE JOBSTEP SECTIONDESTINATION JOBCOORDINATESBASE POINT R1:SLURBT000000EDIT DISPLAY UTILITYDATAShort CutMain MenuCANCELEXECUTE92/210