8-39SIGNALING SYSTEM ELECYES NOThe wiring circuitfrom the turn signalswitch to the turn sig-nal light connector isfaulty and must berepaired.Left turn signal lightPositive tester probe groundNegative tester probe chocolateRight turn signal lightPositive tester probe groundNegative tester probe dark green12 Turn the main switch to “ON”. Set the turn signal switch to “ ” or “ ”. Measure the voltage (DC 12 V) of the choco-late or dark green at the turn signal lightconnector (wire harness side). Is the voltage within specification?1 2This circuit is OK.A BC1. Neutral indicator light (LEDs) Check the neutral indicator light for continu-ity.Refer to “CHECKING THE LEDs”. Are the neutral indicator light OK?EAS008014. The neutral indicator light fails to come on.YES NOReplace the meterassembly.YES NO2. Neutral switch Check the neutral switch for continuity.Refer to “CHECKING THE SWITCHES”. Is the neutral switch OK?Replace the neutralswitch.When you switch the positive and negativetester probes, the readings in the abovechart will be reversed.3. Starting circuit cut-off relay (diode) Disconnect the starting circuit cut-off relaycoupler from the wire harness. Connect the pocket tester (Ω 1) to thestarting circuit cut-off relay coupler asshown. Check the starting circuit cut-off relay forcontinuity.Positive tester probe black/redNegative tester probe sky blueContinuityPositive tester probe sky blueNegative tester probe black/redNocontinuity1221EAS00753NOTE: