INSTRUMENT DESCRIPTION Axioskop 2 plusCarl Zeiss Technical data Axioskop 2 mot plus1-16 B 40-075 e 10/031.8 Technical DataDimensions (width x depth x height)Axioskop 2 plus / mot plus with phototube and HAL 100................ approx. 280 mm x 600 mm x 475 mmAxioskop 2 plus / mot plus with phototube and HBO 103 ............... approx. 280 mm x 733 mm x 475 mmAxioskop 2 plus / mot plus with ergo-phototube and HAL 100........ approx. 280 mm x 670 mm x 500 mmAxioskop 2 plus / mot plus with ergo-phototube and HBO 103 ....... approx. 280 mm x 800 mm x 500 mmWeightAxioskop 2 plus .................................................................................................................approx. 18.4 kgAxioskop 2 mot plus ..........................................................................................................approx. 22.4 kgAmbient conditionsTransport (in packaging):Permissible ambient temperature ..........................................................................................-40 to +70 °CStorage:Permissible ambient temperature .........................................................................................+10 to +40 °CPermissible humidity (without condensation)............................................................... max. 75 % at 35 °COperationPermissible ambient temperature ..........................................................................................+5 to + 40 °CPermissible relative humidity ....................................................................................... max. 75 % at 35 °CAltitude .................................................................................................................................max. 2000 mAtmospheric pressure ................................................................................................800 hPa to 1060 hPaPollution degree ...................................................................................................................................... 2Operating dataOperation..............................................................................................................................closed roomsProtection class......................................................................................................................................... IEnclosure protection.......................................................................................................................... IP 20Electrical safety................................................................ in compliance with DIN EN 61010 (IEC 61010-1)including CSA and UL directivesOvervoltage category............................................................................................................................... IIRadio interference suppression ........................................................ in accordance with EN 55011, Class BNoise immunity ...............................................................................in accordance with DIN EN 61326/ A1