3Com Switch 8800 Configuration Guide Chapter 49 NTP Configuration49-9server: Allow local NTP time service request and control query. However, the localclock will not be synchronized by a remote server.peer: Allow local NTP time service request and control query. And the local clock willalso be synchronized by a remote server.49.2.8 Setting Maximum Local SessionsThis configuration task is to set the maximum local sessions.Perform the following configurations in system view.Table 49-13 Set the maximum local sessionsOperation CommandSet the maximum local sessions ntp-service max-dynamic-sessionsnumberResume the maximum number of localsessionsundo ntp-servicemax-dynamic-sessionsnumber specifies the maximum number of local sessions, ranges from 0 to 100, anddefaults to 100.49.3 Displaying and Debugging NTPAfter completing the above configurations, you can use the display command to showhow NTP runs and verify the configurations according to the outputs.In user view, you can use the debugging command to debug NTP.Table 49-14 Display and debug NTPOperation CommandDisplay the status of NTP service display ntp-service statusDisplay the status of sessions maintained byNTP servicedisplay ntp-service sessions[ verbose ]Display the brief information about every NTPtime server on the way from the localequipment to the reference clock source.display ntp-service traceEnable NTP debugging debugging ntp-service